Machine repeatability
Can the configured machine deliver a consistent sequence with the defined product, settings, head and pack?
Define accuracy as a test method, not an unsupported percentage. State the product, temperature, target quantity, container, tare, sample sequence, machine settings and acceptance rule. A volumetric filler can be checked by mass, but density and temperature must be considered when mass is used to assess a volume dose.
Machine repeatability, process capability and legal packaged-goods compliance are related but different questions. A factory trial can show how a configured filler performs under stated conditions; the packer remains responsible for the production checking system, suitable measuring equipment, records and any legal obligations that apply to the finished goods.
Can the configured machine deliver a consistent sequence with the defined product, settings, head and pack?
Can the site detect drift, correct settings and release packs under normal batch, operator and environmental variation?
Does the finished packing and checking system meet the applicable quantity, equipment and record requirements?
| Test input | What to record | Why it matters |
|---|---|---|
| Product condition | Batch, temperature, mixing history, aeration, settling and particle distribution. | Viscosity, density and chamber refill can change during the run. |
| Target and method | Nominal quantity, whether the machine doses by volume or another method, and whether checks are by mass, volume or level. | The measurement must represent the production requirement. |
| Container and tare | Container lot, empty-pack weight method, closure or lid inclusion and balance resolution. | Variable tare can hide or exaggerate fill variation. |
| Machine identity | Machine, dosing module, head, valve, nozzle, recipe and relevant utility settings. | Results are not transferable to an unidentified configuration. |
| Sample sequence | Priming, start-up, consecutive steady-state packs, planned pauses and end-of-batch samples. | Drift and restart behaviour may not appear in isolated samples. |
| Acceptance rule | Sample count, limits, actions on failure and who approves the result. | A result cannot be judged consistently without a pre-agreed rule. |
Mass checks are often practical, but the conversion between volume and mass depends on product density. If temperature, aeration, composition or settling changes density, a stable weight does not necessarily prove a stable volume and vice versa. Record the density basis and product condition used for any conversion.
Use the existing viscous-product accuracy guide for sequential checks and the sample trial guide for representative product conditions.
UK Government guidance explains the minimum and average systems for packaged goods and the associated checking responsibilities. It also states that equipment used to weigh or measure packaged goods must be suitable and that records are required in defined circumstances. Review the current packaged-goods guidance and equipment and records guidance, then obtain application-specific advice from Trading Standards where required.
Send the product, target quantity, pack, proposed check method, sample expectation and target accepted output. Lancing can define what the machine trial can prove and what remains part of your site control system.
There is no universal sample count for every purpose. The protocol should reflect the decision being made, the number of heads, expected variation, run length and applicable quality or legal requirements. Consecutive samples are more informative than isolated selected packs.
Possible causes include product temperature, aeration, settling, hopper level, incomplete chamber refill, valve leakage, seal wear, utility changes and container tare. Record the sequence and operating conditions before adjusting the whole machine.
Consider it when every pack needs an automatic weight decision, when trend feedback is part of the control strategy, or when the line needs automated reject handling. The weighing range, pack stability, line speed and legal-metrology duty must be specified separately.
No. A percentage without product, quantity, dosing module, machine configuration, sample method and test conditions is not a complete claim. Request evidence for the actual application and intended acceptance method.